Radiofrequency (RF) Generators, Electrodes, and Cannulas for Pain Management and Neurosurgery - Cosman Medical

Radiofrequency for Pain Management and Neurosurgery      

Tel: +1 781 272 6561   Fax: +1 781 272 6563      

Displaying items by tag: CC
The CSK-3M-R autoclavable thermocouple electrodes feature integral 3-meter cables for direct connection to a Radionics® radiofrequency generator, such as the RFG-3C plus. Compatible with straight and curved RF cannulae of matching length (CC, RFK).  Compare to the Valleylab® Sluijter-Mehta Electrodes (SMK).

Reusable Electrode Brochure (CSK)

Request Information

The CSK-3M autoclavable thermocouple electrodes feature integral 3-meter cables for direct connection to a Cosman radiofrequency generator. Compatible with straight and curved RF cannulae of matching length (CC, RFK).

Reusable Electrode Brochure (CSK)

Request Information

Request Information

 

Cosman radiofrequency (RF) cannulae are used with thermocouple electrodes, such as the Cosman CSK, TCN, TCD electrodes, for temperature-controlled RF lesioning for the treatment of pain.  RF cannulae are typically used to access nervous structures around the spinal, such as the medial branch, dorsal root ganglion, sympathetic chain, and gray ramus communicans.  Or, they can be used to target more peripheral nerves such as the suprascapular, splanchnic, and inferior calcaneal.  Anesthetics, steroids, contrast and other fluid agents can be injected through a cannula's hollow interior, which also accepts an electrode for RF lesioning.

Cosman RF cannulae come in a wide variety of shapes and size to suit doctor preference and clinical objectives:

  • Lengths: 5, 10, 15, 20 cm
  • Tip Exposure: 2, 4, 5, 6, 10, 15, 20 mm
  • Diameter: 22, 21, 20, 18, 16 gauge
  • Straight or Curved
  • Sharp or Blunt
  • Siliconized (white insulation) or Standard (black insulation)

Each Cosman RF cannula features an ergonomic hub, a stiff steerable shaft, and specially tapered insulation at the tip to facilitate insertion and maneuvering.  The cannula is colored coded by length and is compatible with all Cosman electrodes of matching length, including the reusable Nitinol (TCN), reusable stainless steel (CSK), and disposable (TCD) models.

 

 Siliconized Sharp Cannula (White Insulation)

Length (cm)

Tip (mm)

Gauge (ga)

Part Number (10/pk)

Straight   5
4 22 CC5422Z-P
Straight   10 5 22 CC10522Z-P
Straight   10
10 22 CC101022Z-P
Curved   10
10 22 RFK-C101022SZ-P
Straight   10
10 20 CC101020Z-P
Curved   10
10 20 RFK-C101020SZ-P
Straight   15
10 20 CC151020Z-P
Curved   15
10 20 RFK-C151020SZ-P

 

 16 Gauge Curved Sharp Cannula

Length (cm)

Tip (mm)

Gauge (ga)

Part Number (10/pk)

5 6 16 RFK-C5616S-P
5 10 16 RFK-C51016S-P
10 6 16 RFK-C10616S-P
10 10 16 RFK-C101016S-P
15 6 16 RFK-C15616S-P
15 10 16 RFK-C151016S-P

 

Straight Sharp Cannula

Length (cm)

Tip (mm)

Gauge (ga)

Part Number (10/pk)
5 4 22 CC5422-P
5
4 22 CC5422Z-P Siliconized
5 4 21 CC5421-P
5 10 21 CC51021-P
10 2 22 CC10222-P
10 5 22 CC10522-P
10 5 22 CC10522Z-P Siliconized
10 5 21  CC10521-P
10 5 20  CC10520-P
10 5 18 CC10518-P
10 10 22 CC101022-P
10 10 22 CC101022Z-P Siliconized
10 10 21 CC101021-P
10 10 20 CC101020-P
10 10 20 CC101020Z-P Siliconized
10 10 18  CC101018-P
15 5 20 CC15520-P
15 5 18 CC15518-P
15 10 20  CC151020-P
15 10 20 CC151020Z-P Siliconized
15 10 18  CC151018-P
15 15 20  CC151520-P
15 20 20  CC152020-P
20 5 20  CC20520-P
20 10 20  CC201020-P

 

 Curved Sharp Cannula

Length (cm)

Tip (mm)

Gauge (ga)

Part Number (10/pk)

5 4 22 RFK-C5422S-P
5 6 16 RFK-C5616S-P
5 10 16 RFK-C51016S-P
10 5 20 RFK-C10520S-P
10 5 18 RFK-C10518S-P
10 6 16 RFK-C10616S-P
10 10 22 RFK-C101022S-P
10 10 22 RFK-C101022SZ-P Siliconized
10 10 20 RFK-C101020S-P
10 10 20 RFK-C101020SZ-P Siliconized
10 10 18 RFK-C101018S-P
10 10 16 RFK-C101016S-P
15 5 20 RFK-C15520S-P
15 5 18 RFK-C15518S-P
15 6 16 RFK-C15616S-P
15 10 20 RFK-C151020S-P
15 10 20 RFK-C151020SZ-P Siliconized
15 10 18 RFK-C151018S-P
15 10 16 RFK-C151016S-P
15 15 20 RFK-C151520S-P
20 5 20  RFK-C205020S-P
20 10 20  RFK-C201020S-P

 

 Curved Blunt Cannula

Length (cm)

Tip (mm)

Gauge (ga)

Part Number (10/pk)

10
5 20 RFK-C10520B-P
10
10 20 RFK-C101020B-P
15
5 20 RFK-C15520B-P
15
10 20 RFK-C151020B-P

 

Straight and Curved Cannula Brochure (CC, RFK)

Request Information

 

* NeuroTherm, NT1000, NT1100, NT2000, NT500, NT250 are trademarks or registered trademarks of NeuroTherm, Inc.
* Cotop, CXE, CX, RCN, SMK, CdisK are trademarks or registered trademarks of Cotop International B.V. or NeuroTherm, Inc.
* Stryker, MultiGen are trademarks or registered trademarks of Stryker Corporation.
* Kimberly-Clark, ThoraCool, TransDiscal, TransDiscal System, SInergy, SInergy System are trademarks or registered trademarks of Kimberly-Clark Worldwide, Inc.
* Baylis, Baylis Medical, BMC are a trademarks or registered trademarks of Baylis Medical Company, Inc. or Kimberly-Clark Worldwide, Inc.
* Radionics, CRW, BRW are trademarks or registered trademarks of Integra Radionics, Inc.
* RFG-3C, RFG-3C plus, Disctrode, Valleylab are trademarks or registered trademarks of Covidien AG.

Published in Radiofrequency Cannula

Each Cosman disposableTC radiofrequency electrode (TCD) comes sterile-packed to eliminate sterilization logistics and the possibility of disease transmission.  Use as a backup in case a reusable electrode is accidently contaminated.

Disposable Electrode Brochure (TCD)

Request Information

Made from robust, stainless steel shafts, CSK radiofrequency thermocouple electrodes are designed for repeated autoclaving and reuse in multiple patients.  Compatible with straight and curved RF cannulae of matching length (CC, RFK).

Reusable Electrode Brochure (CSK)

Request Information

Made from super-flexible Nickel-Titanium "memory metal", Cosman Nitinol TC radiofrequency electrode (TCN) are designed for enhanced durability to daily use and repeated autoclaving.  Compatible with straight and curved RF cannulae of matching length (CC, RFK).

Nitinol Reusable Electrode Brochure (TCN)

Request Information